5-2 EM-506 (N-07/03)
CINCINNATI INCORPORATED can provide many
other types of standard and special dies, some of which
are shown in Figure 5-4.
FIGURE 5-4 Types of dies
DIE SETS: Special care and precautions should be
taken when operating die sets with guide pins and
bushings.
Depending on the working height of the die set, the
full stroke return may cause the die set guide pins and
bushings to separate. Re-entry of the guide pins into
the bushings may be difficult, if not impossible. Each
die set application should be reviewed for this
condition.
CINCINNATI INCORPORATED recommends that
the working height of all die sets be such that the
bushings never leave the guide pins when the ram
makes a full up stroke.
TOOL INSTALLATION
To install the tooling, use the following procedure:
1. If the PROFORM is not already powered-up, turn
ON the main disconnect switch on the electrical
enclosure.
2. Depress the Main Drive START button on the
PROFORM PC Control. Hold the button until the
motor starts.
3. Log on to the PROFORM PC Control and verify that
the palmbuttons are enabled for SETUP mode. To
do this, press the OP STATION button in the
toolbar.
Click on the SETUP mode tab of the Operator
Stations dialog.
Ensure that the Station 1 checkbox is checked. If it is
not already checked, click on the white box to the
left of the “Station 1” label to enable it. Then press